Can inertial movement sensors (IMUs) provide a valid and reliable way of measuring Spinal Mobility in Axial Spondylo-arthritis (axSpa)? A clinimetric evaluation

Concept

The main objective of this project is to test the accuracy and reliability of electronic sensors in measuring spinal movement and to develop a new outcome tool for spinal mobility. Current methods rely on tape measures/goniometers and are not reliable/responsive enough to evaluate new treatments for axSpa. We have now completed three validation studies – a reliability study, a criterion validity study comparing sensor accuracy to the UCOTrack© gait lab system, and an exploratory ambulatory study.

A multi-centre study is underway testing the responsiveness of our IMU spinal mobility index alongside MRI pre/post biologics. We have also developed a smartphone app to allow researchers to use these electronic spinal mobility tools.

Facts and Figures

Project Lead
P Gardiner
Western Health and Social Care Trust
pvgardiner@yahoo.co.uk
FOREUM resarch grant: € 270.000
2017–2021

Meet the Team

Project Lead

P Gardiner
Western Health and Social Care Trust
pvgardiner@yahoo.co.uk
E Collantes Estevez
Fundacion para la Investigacion Biomedica de Córdoba
J L Garrido Castro
University of Cordoba
J Condell
University of Ulster
P Machado
University College London
F Wilson
Trinity College Dublin

Final Results

One of our early studies led by Philip Gardiner (Londonderry, UK) involved testing 40 patients with axSpA to find out if measurements of spinal mobility using the ViMove© sensor (DorsaVi) were reliable. The results confirmed that sensor measurements remain the same no matter which therapist was doing the test or if the test was repeated a week later. This is the first such study to demonstrate the reliability of spinal rotation tests, previously thought to be a weakness of older IMU technology. A composite score (IMU-ASMI) was developed, combining all of the planar movements in the cervical and lumbar spine to generate a new and reliable outcome score for spinal mobility. 

The other core validation study led by Juan-Luis Garrido-Castro and Eduardo Collantes-Estevez (Cordoba, Spain) involved testing the sensor measurements against an accurate electronic motion detection system. Motion capture systems are widely regarded as the gold standard for measuring body movement accurately. This team had previously developed and validated the UCOTrack© motion capture system specifically to measure spinal mobility in axSpA. Their study established that ViMove© sensor tests have a high degree of accuracy, comparable to that of their motion capture system. A strong correlation was found between spinal mobility tests and structural damage scores based on x-rays. Their study also provided validation of a new sensor positioning protocol which includes the thoracic segment of the spine, particularly relevant for axSpA clinical studies. 

The third study led by Fiona Wilson (Dublin, Ireland) recruited another group of 40 axSpA patients to test whether or not sensor tests of movement and function can be carried out accurately at home. In this study, patients carried out movement tests in clinic with and without supervision and then again at home using recorded video instructions. Patients then continued to wear them for up to 24 hours alongside completing some questionnaires and a symptom/activity diary. During this period they carried out several standardised functional tests. This study has demonstrated for the first time that unsupervised range of movement tests can be carried out accurately without supervision by following video instructions. These results open up new possibilities both for clinical research and for patient self-management.

The fourth pilot study in Cordoba tested the sensitivity to change of sensor tests against the UCOTrack system in 20 patients before and after starting biologic drugs. This study has shown that both the UCOTrack system and the IMU based spinal mobility score have significantly greater responsiveness to change compared to BASMI. This was part of a three-centre observational study using concurrent spinal mobility tests and MRI outcome scores led by Pedro Machado (London, UK) including Londonderry as a third study site. This MRI study is still underway, but we are confident that it will provide further information on the relationship between changes in MRI inflammation and changes in spinal mobility scores.

Lay Summary

Several meetings have been held in Londonderry with a patient interest group both at the design stage and when results have become available. Letters have been sent out to all participants in our reliability study to inform them of the results. 

In Spain, a first meeting has been held for patients at initial stages. Some preliminary results have been presented to representatives of CEADE in their annual congress. During the national congress of family medicine for chronic patients (SEMERGEN 2018), patients and members of our research group presented an oral communication titled “keep moving: devices for evaluation and monitoring of mobility in rheumatic patients.”, which won the prize of the best oral communication of the congress.
 

Publications

  • Gardiner, Small, D., Muñoz-Esquivel, K., Condell, J., Cuesta-Vargas, A., Williams, J., Machado, P. M., & Garrido-Castro, J. L. (2020). Validity and reliability of a sensor-based electronic spinal mobility index for axial spondyloarthritis. Rheumatology (Oxford, England), 59(11), 3415–3423. doi.org/10.1093/rheumatology/keaa122
    Read more
  • Aranda-Valera IC, Cuesta Vargas A, Garrido-Castro JL, Gardiner PV, Lopez-Medina C, Machado P, Condell J, Connolly J, Williams JM, Munoz-Esquivel K, O’Dwyer T, Castro-Villegas MC, Gonzalez-Navas C, Collantes-Estevez E. Measuring Spinal Mobility using an inertial measurement unit system: a validation study in axial spondyloarthritis. Diagnostics 2020;10:426
    Read more
  • Gardiner PV, Small D, Muñoz-Esquivel K, Condell J, Cuesta-Vargas A, Williams J, Machado PM, Garrido-Castro JL. Validity and Reliabilty of a Sensor Based Electronic Mobility Index for Axial Spondyloarthritis Rheumatology (Oxford) 2020 Apr 28;keaa122. doi.org/10.1093/rheumatology/keaa122
    Read more

EULAR & ACR Abstracts

2018

  • C. Aranda-Valera, J. L. Garrido-Castro, I. Martinez-Sanchez, C. Gonzalez2, P. Gardiner, P. M. Machado, E.Collantes Inertial Motion Sensors Using The ViMove© System Is A Valid Method To Assess Spinal Mobility In Patients With Axial Spondyloarthritis Ann Rheum Dis, volume 77, supplement Suppl, year 2018, page A642
  • C. Aranda-Valera, S. Alcaraz-Clariana, L. Garcia-Luque, J. L. Garrido-Castro, I. Martinez-Sanchez, C. Gonzalez, P. Gardiner, P. M. Machado, E. Collantes1 on behalf of iMaxSpA Study Group. Lumbar muscles stiffness in patients with axial spondyloarthritis is altered in comparison with healthy subjects. Ann Rheum Dis, volume 77, supplement Suppl, year 2018, page A1561
  • J. L. Garrido-Castro, I. C. Concha-Aranda, P. Gardiner, P. M. Machado, J. Williams, E. Collantes-Estevez Axial spondyloarthritis posture assessment using inertial sensors Ann Rheum Dis, volume 77, supplement Suppl, year 2018, page A1561
  • I.C. Aranda-Valera, L. Garcia-Luque, S. Alcaraz-Clariana, J. L. Garrido-Castro, I. Martinez-Sanchez, C. Gonzalez, P. Gardiner, P. M. Machado, E. Collantes Advanced metrology in patients with axial spondyloarthritis: lumbar or thoracic + lumbar measurements for spinal mobility assessment? Ann Rheum Dis, volume 77, supplement Suppl, year 2018, page A1560
  • Gardiner P, Small D, Boyle E, Conlon AM, da Silva JAP, Condell J, Cuesta-Vargas A, Collantes-Estévez E, Garrido-Castro JL. Validation of a New Electronic Spinal Mobility Index for Patients with Axial Spondyloarthritis Based on Inertial Motion Unit (IMU) Sensors [abstract]. Arthritis Rheumatol. 2018; 70 (suppl 10).

2019

  • THU0380: Lumbopelvic rhythm in patients with Axial Spondyloarthritis compared with low back pain and healthy subjects
  • SAT0659: Applying the OMERACT truth filter to a new electronic spinal mobility index for Axial Spondyloarthritis based on inertial measurement unit (IMU) sensors
  • SAT0327: Segmental relationship between mobility, structural damage and disease activity in Axial Spondyloarthritis

2021

  • Juan L. Garrido-Castro, Inmaculada Concepcion Aranda-Valera, Philip Gardiner, Pedro Machado, Joan Condell, Cristina Gonzalez-Navas, Eduardo Collantes Estevez. Responsiveness of spinal mobility measurements in axial spondyloarthritis using conventional and advanced metrology: a pilot study. Ann Rheum Dis, volume 80, supplement 1, year 2021, page 740


Go to EULAR Abstract Archive

Patient Voice

Patient research partners in Spain and the UK have attended workshops to discuss the project. Patients are also involved in the design process for the smartphone application. The feedback from patients involved in home measurement testing has been very positive.